Accumulator Charge Tester
Accumulator Charge Tester
Application:
Used for intelligent battery charging, charging current: 0-100A continuous adjustable, can meet the battery charging maintenance.
Features:
◆Single monitoring module adopts remote radio frequency wireless communication for voltage data
Applicable Battery | DC48V |
Charge Voltage | DC42V-60V |
Charge Current | 100A |
Working Mode | Single machine mode, parallel host mode, parallel slave mode, remote controlled mode |
transmission, and can be set up to 4 independent frequency bands, that is, can be in the same area at most 4 sets of monitoring systems at the same time for data transmission, without mutual interference or channing.
◆Wireless acquisition box can monitor each battery, realize the complete monitoring of the battery pack discharge process, and has three data acquisition methods:
1. Data is transmitted between the monomer monitoring module and the charge and discharge instrument host.
2, data transmission between the single monitoring module and the USB wireless terminal.
3, single monitoring module and charger host, USB wireless terminal, data transmission between the three.
◆Each charging and discharging device can monitor 25 individual collection boxes, each individual collection box can be connected to 12 batteries, a total of 300 batteries can be monitored. The device can automatically select the highest 6 section numbers and voltage values, and display them in different colors on the display screen.
◆The voltage of a single unit can be displayed in a sliding table or a sliding bar chart.
◆It is equipped with PC software, which can analyze the recorded data such as total voltage, charging current and voltage of each single battery, and generate corresponding data reports. Intuitively reflect the battery performance curves, graphs, reports, etc., and can be printed and queried.
◆The device is equipped with a USB port. The charging data can be stored in the USB flash drive and then imported to the PC. PC data management software can analyze the process of battery charging and generate the corresponding data report, so that the data transfer is more convenient.
◆It adopts intelligent single chip ARM control, 7 inch 1024*600 HD LCD display, resistive touch operation, built-in Chinese and English switching menu, menu operation is simple and clear.
◆Automatic protection stop function, over temperature protection, over voltage protection, over current protection, reverse alarm protection, the display screen can display the corresponding alarm when any alarm stops, over voltage protection, reverse alarm protection automatically disconnect the air circuit breaker.
◆The charging termination conditions can be set, including high voltage of a single battery, high voltage of the whole group, charging time to, and charging capacity to. When any condition is reached, the device will automatically stop the test with a buzzer prompt tone and automatically record the reason for stopping.
◆With RS485 remote control charging function.
◆It has the function of multi-machine parallel charging. It only needs to operate on the display of the device whose parallel parameter is the host. The device whose parallel parameter is the slave can automatically follow the instructions of the host to distribute power evenly, and start and stop operation.
Specifications:
Applicable Battery | DC48V |
Charge Voltage | DC42V-60V |
Charge Current | 100A |
Working Mode | Single machine mode, parallel host mode, parallel slave mode, remote controlled mode |
Protection Capacity | Battery test voltage over-voltage protection, under-voltage shutdown, over-current protection, reverse protection, 65℃ over-temperature protection, and has LCD warning, buzzer alarm |
Single cell voltage acquisition (optional) | The use of multi-band radio frequency wireless module, communication distance up to 100 meters, compatible with 2V/4V/6V/12V single battery voltage monitoring, 1 to 25 groups of radio frequency wireless monitoring module, up to 300 batteries can be monitored, a single wireless monitoring module can monitor 12 single batteries. |
Control accuracy | Charging current ≤±1%(FS); Group terminal voltage ≤±0.5%(FS); Single cell voltage: ≤±0.1%(FS) |
PC communication | RS485 interface, USB interface, RF radio frequency communication 433M |
Data storage capacity | Built-in SD card 16G capacity, transfer to U disk 16G capacity |
Working Environment | |
Dissipate heat | forced air cooling |
Temperature | Operating range: -5 ~ 50℃ ,Storage temperature: -40 ~ 70℃ |
Humidity | Relative humidity 0~90% (40±2℃) |
Altitude | Rated at 4000 meters above sea level |
Noise | <75dB |
Working Power | |
Voltage | Power supply: single-phase AC220V (-20% ~ +30%), frequency :45 ~ 65Hz; Charging power supply: refer to the nameplate parameters or chassis identifier |
Voltage withstand test | Input to housing: 2200V DC 1min Input to output: 2200V DC 1min Output to housing: 700VDC 1min |
Safety | Conform to EN610950 |
Wire Connection | |
AC input | National standard male socket, suitable for 1 ~ 1.5mm2 cable |
Charging current cable | Cable quick connector (red positive black negative), specific size refer to "Packing list" |
Parallel cable (optional) | 2m 6-core crystal plug cable |
Note: Other voltage level and current level instruments can consult our company